ZAPP-ZIMMERMANN GmbH
MenuSearch
Close
  • Firestop Systems: ETA
    • Penetration Seals
      • Mixed Penetration Seals
      • Cabel Penetration Seals
      • Pipe Penetration Seals
      • Fire Protection Joint Seals
  • Firestop Systems: UL
    • Penetration Seals
      • Mixed Penetration Seals
      • Cabel Penetration Seals
      • Pipe Penetration Seals
      • Blank Opening
  • Building materials / components
    • Services of ZAPP-ZIMMERMANN GmbH
    • Support in development and approval processes
    • Application examples for the intumescent behaviour
    • Positive material properties combined with fire resistance
    • Manufacturing of fire protection powder
    • Overview - Building materials
    • Overview: System components
    • Overview: Components for further processing
  • Company
    • History
    • Certified safety
    • National and international approvals
  • Downloads
  • Contact
  • Partner
  • Youtube
  • Twitter
  • Xing
  • linkedin
  1. Innovative Fire Safety Systems
  2. Firestop Products
ZZ 330, 6er Set (ZZ-Brandschutzschaum 2K NE)
ZZ 330, 6er Set (ZZ-Brandschutzschaum 2K NE)

ZZ® 330 Fire Protection Foam, 6pc.-set

In addition to its outstanding technical fire safety properties, ZZ® 330 Fire Protection Foam, 6pc.-set is particularly characterised by its easy processing. It can be used as a mixed penetration seal
(EI 90), as well as a pure cable penetration seal (EI 60/ EI 90/ EI 120). The optimal match between the
beginning of the reaction and hardening enables sufficiently long work interruptions for the user, as well
as fast work progress. Thanks to the high viscosity, the user does not have to deal with foam running out of
the penetration seal. After hardening, the permanently elastic structure of the penetration seal enables easy
retroactive-installation.

Accessory information

Name ZZ® 330 Fire Protection Foam, 6pc.-set
Manufacturer ZAPP-ZIMMERMANN
DesignationArt.-Nr.VE
ZZ® 330 Fire Protection Foam, 6pc.-setB15N01-01061

Detailinformationen

Downloads
  • Technisches Datenblatt
  • Sicherheitsdatenblatt
  • Leistungserklärung
  • Leistungserklärungrev3
Additional Information

Additional Information

Product Information

6 x 380 ml cartrdige, incl. accessories

Packaging units1
ColorRed-brown
Content12.85 fl. oz
Transport / storagedry in original containers
storage temperature5 °C – 30 °C
coating materialsPlastic dispersion paint, alkyd resin paint, polyurethane acrylic paint, epoxy resin lacquer
Gaseous chemicalsShort-term storage above concentrated ammonium hydroxide solution
safety instructionsPlease refer to the safety data sheet.
Compression hardnessCv (40%) = 18kPa Test standard: DIN EN ISO 3386-1
Thermal stressContinuous contact or ambient temperature: ≤ 80 °C
Indoor air hygieneAnforderungen nach AgBB-Schema 2015 werden erfüllt Prüfnormen: prEN 16516, ISO 16000-3, ISO 16000-6, ISO 16000-9
Surface resistivity R0 = 2 x 109 Ω Test standard: BGR 132:2003 (2.6), DIN IEC 60167 (For requests for installation in hazardous areas please contact ZAPP-ZIMMERMANN GmbH)
airborne sound insulationDn,e,w(C;Ctr) = 66 (-1; -7) dB Rw(C;Ctr) = 47 (-1; -7) dB Prüfnorm: EN ISO 717-1 (Probekörperabmessungen 350 x 350 x 170 [mm], geprüft ohne Installationen), Dn,e,w(C;Ctr) = 62 (-1; -4) dB Rw(C;Ctr) = 43 (-1; -4) dB; Prüfnorm: EN ISO 717-1 (Probekörperabmessungen 350 x 350 x 120 [mm], geprüft ohne Installationen)
Thermal conductivityλ = 0,088 W/(m*K); R = 0,279 m²*K/W; Prüfnorm: DIN EN 12667
Resistance to static differential pressurePmax = 8800 Pa Prüfnorm: In Anlehnung an EN 12211 (Probekörperabmessungen 360 x 360 x 144 [mm], geprüft ohne Installationen), Pmax = 10000 Pa Prüfnorm: In Anlehnung an EN 12211 (Probekörperabmessungen 350 x 350 x 200 [mm], geprüft ohne Installationen)
Air permeabilityQ600≤ 0,08 m³/(h*m²) (bei 600 Pa Differenzdruck konnte bei einer Messgenauigkeit von 0,01 m³/h keine Luftdurchlässigkeit gemessen werden) Prüfnorm: EN 1026 (Probekörperabmessungen 350 x 350 x 200 [mm], geprüft ohne Installatio, Q50 = 0,39 m³/(h*m²) Prüfnorm: EN 1026 (Probekörperabmessungen 360 x 360 x 144 [mm], geprüft ohne Installationen)
Expansion ratio1,6-fach bis 4,5-fach Geprüft an Proben bei 450 °C über 25 Minuten mit Auflast. Der Auf-schäumfaktor ist ein Laborkennwert. Das Aufschäumverhalten im Einbauzustand hängt von den vorhandenen Randbedingungen ab.
Expansion pressureNo expansion pressure measurable
Classification of the reaction to fire according to DIN EN 13501-1Class E
Building material classDIN 4102-B2
Bulk densityρ ≥ 215 kg/
CutabilityAfter approx. 90 seconds (at 72 °F /22 °C material temperature and ambient temperature)
Work interruptionApprox. 50 seconds (at 22 °C material temperature and ambient temperature) The specifications vary depending on the material and ambient temperature.
Foam yieldUp to 2.1 litres (at 22 °C material temperature and ambient temperature)
Application temperature59 °F to 86 °F (15 °C to 30 °C), recommended: 68 °F – 77 °F (20 °C to 25 °C)

Stay informed with the free newsletter of ZAPP-ZIMMERMANN GmbH

Subscribe now

Sign up
Profi Chat



Immer gut informiert mit dem
Newsletter der ZAPP-ZIMMERMANN GmbH


Jetzt abonnieren

Overview

  • Imprint
  • Legal Notice
  • General Terms and Conditions

Contact

ZAPP-ZIMMERMANN GmbH
Marconistraße 7-9
50769 Cologne - Germany

fon: +49 221 97061-0
fax: +49 221 97061-929

Contact form

Certified

TÜV Rheinland